Environment & Safety Gas Processing/LNG Maintenance & Reliability Petrochemicals Process Control Process Optimization Project Management Refining

Heat Transfer

Mitigate fouling in crude unit overhead—Part 3

CH2M Hill: Sloley, A. W.

CASE STUDYThe basis for this case study is shown in Fig. 18; it is a crude unit with overhead heat integration. This is a one-drum overhead system with heat integration and no water wash. In an attemp..

Mitigate fouling in crude unit overhead—Part 2

CH2M Hill: Sloley, A. W.

Up to 50% of the refinery’s entire corrosion expense may occur in the crude unit. The root causes of the fouling and corrosion issues are often linked to the basic unit configuration choices, as ..

Improve solvent recovery in wax production

CSIR-Indian Institute of Petroleum: Garg, M. O.  |  Kumar, S.  |  Nanoti, S. M.  |  Ghosh, P.

The solvent-recovery section of the deoiling unit for wax production consumes substantial energy. In this study, the effects of operating conditions (pressure), energy consumption and cost, and proces..

Update temperature control for a Claus unit with neural networks

North-West University, School of Chemical and Minerals Engineering: Schabort, C. J.  |  Neomagus, H. W. J. P.

The Natref oil refinery in Sasolburg, South Africa, had experienced refractory problems in the sulfur recovery unit’s (SRU’s) combustion chamber since startup (Fig. 1). Even though the SRU w..

HP Innovations

Hydrocarbon Processing Staff: Blume, Adrienne

ClearSign marks NOx reduction milestoneClearSign Combustion Corp. has cost-effectively reduced NOx to a record-setting 3 ppm. The results indicate that ClearSign’s technology may overcome many of..

Foster Wheeler to supply fired heaters for Russia refinery expansion

“The supply of all of the fired heaters required for this new complex at one of the largest refineries in Russia is one of the biggest and most critical packages we have awarded, and we are pleased to have selected Foster Wheeler,” said V.E. Somov, general director of Kirishinefteorgsyntez.

HP Innovations

Hydrocarbon Processing Staff: Blume, Adrienne

Burner management system ideal for retrofitsPrincipal Technology Inc. offers a modern burner management system (BMS) (Fig. 1) specifically designed for the retrofit of legacy boilers, ovens, furnaces ..

Mitigate fouling in crude unit overhead—Part 1

CH2M Hill: Sloley, A. W.

In a refinery crude distillation column, up to 40% of the total heat removal may be found in the tower overhead condenser. The quantity of duty available makes heat integration (HI) between the column..

Improve pressure drop calculations for saturated water lines

When saturated water flows through pipes and components, it flashes—thus increasing its specific volume and limiting the fluid flowrate. Due to these conditions, the calculation and design for pi..

Achieve uniform heat flux in a coker furnace

Reliance Industries Ltd.: Patil, R.  |  Mishra, V. P.  |  Das, A. K.

A delayed coker unit thermally cracks vacuum residue (VR) and converts it into products like liquefied petroleum gas (LPG), naphtha, gasoil and petroleum coke. A majority of the thermal cracking takes..