Environment & Safety Gas Processing/LNG Maintenance & Reliability Petrochemicals Process Control Process Optimization Project Management Refining

Sofronas, A.

Consulting Engineer, Houston, Texas

Tony Sofronas, D. Eng, was the worldwide lead mechanical engineer for ExxonMobil Chemicals before retiring. He now owns Engineered Products, which provides consulting and engineering seminars on machinery and pressure vessels. Dr. Sofronas has authored two engineering books and numerous technical articles on analytical methods.

HP Engineering Case Histories: Case 71: Statistical visual data can be useful in troubleshooting—Part 1

Consulting Engineer: Sofronas, A.

I’ve spent many years troubleshooting equipment, along with investigative research. In research-statistical design, data analysis is frequently used when test information is available. This artic..

HP Engineering Case Histories: Case 70: Twenty rules for troubleshooting

Consulting Engineer: Sofronas, A.

In previous Engineering Case History columns, I have discussed checklists and their value in avoiding errors during startups. While the rules cannot replace common sense or a logical and methodical ap..

HP Engineering Case Histories: Case 69: Heat-up rate and rubs on a steam turbine

Consulting Engineer: Sofronas, A.

This column has suggested using simple analytical models to troubleshoot equipment. However, in some cases, a more detailed solution may be required. The following case histories examine the heat up o..

Case 68: Pneumatic testing dangers

Consulting Engineer: Sofronas, A.

Use caution on what defines a true ‘safe distance’

Case 67: Extruder blowback

Consulting Engineer: Sofronas, A.

Understanding what is happening can lead to a solution

Case 66: Fiberglass mixing tank flexing vibration

Consulting Engineer: Sofronas, A.

The design of fiberglass and polymer tanks had many problems in the 1980s. Most of these problems were resolved with experience, new materials and manufacturing techniques, along with new national con..

Case 56: Quick troubleshooting of shaft failures

Consulting Engineer: Sofronas, A.

Some simple calculations can guide the way to improved performance

Case 54: Is it motor vibration or some other cause?

Consulting Engineer: Sofronas, A.

It's not always the motor causing the vibration

Case 53: Electrical faults can cause shaft and gear failures

Consulting Engineer: Sofronas, A.

This technique allows transient torques in geared units to be determined

Case 52: Problems with a blocked-in centrifugal pump

Consulting Engineer: Sofronas, A.

The potential for overheating is one of many concerns