Environment & Safety Gas Processing/LNG Maintenance & Reliability Petrochemicals Process Control Process Optimization Project Management Refining

Compressors

HP Engineering Case Histories: Case 75: Analyzing wear when troubleshooting

Consulting Engineer: Sofronas, A.

Wear occurs frequently on machinery. In its simplest terms, it is the undesirable removal of material. When troubleshooting the root cause of wear in equipment, the engineer’s interest should be ..

HP Reliability: Leaders must allocate time for technology updates

Hydrocarbon Processing Staff: Bloch, Heinz P.

Just as a good medical doctor is expected to have wide knowledge on modern treatment options, we would expect reliability professionals to be equally informed on technology advances. There are numerou..

Siemens to supply new compressor trains for three LNG plants in China

The compressor trains in the three plants each consists of a six-stage vertically-split compressor and a Siemens constant speed electric motor. This type of drive and control, using inlet guide vane assemblies, provides more efficient and reliable operation than conventional compressor solutions.

Optimize your compressor maintenance program

Consultant: Geitner, F. K.

One deviation alone might not be enough to bring on a compressor failure, but, when several more deviations combine, the failure risk is known to increase exponentially.

Digital is the solution for modern compressor protection

Hoerbiger Compression Technology: Stachel, K.  |  Locken, T.

Compared to traditional analog communications technologies, digital systems cost less, offer greater flexibility, and are more reliable thanks to built-in self-checking systems and resistance to interference.

Case history: Failure analysis of a syngas compressor

SABIC Technology Centre: van Zyl, G.  |  Al-Zahrani, E.  |  Al-Meshari, A.  |  Al-Haroon, M.

A first-stage impeller in a synthetic gas compressor failed after 20 years of service. The compressor is a six-stage centrifugal compressor driven by a steam turbine. This case history discusses the i..

HP Reliability: Four-stage, low-flow process centrifugal compressor can fill important industry gaps

Hydrocarbon Processing Staff: Bloch, Heinz P.

In the 1970s and 1980s, multistage centrifugal compressors in the 3,000 acfm (about 5,000m3/hr) and lower flow ranges were largely confined to instrument and plant air duties. Three stages with interc..

HP Engineering Case Histories: Case 74: How to determine impact forces when troubleshooting

Consulting Engineer: Sofronas, A.

When troubleshooting failures, it is not unusual for the metallurgical report to indicate that the failure was the result of an impact type of force. The investigator who receives this information mus..

Chevron expands North American compressor oils

Chevron said that Cetus PAO and the rebranded Cetus HiPerSYN (formerly HiPerSYN) have joined Cetus DE to create a family of premium compressor oils formulated for use in a wide range of applications, including portable and stationary rotary screw, rotary vane, and reciprocating compressors.

HP Reliability: Expect adversity, but plan for success

Hydrocarbon Processing Staff: Bloch, Heinz P.

Consider that a major oil refinery was planning a substantial modernization project in 2008. Energy efficiency gains and the ability to process a more readily available crude slate were key motivating..