Environment & Safety Gas Processing/LNG Maintenance & Reliability Petrochemicals Process Control Process Optimization Project Management Refining

Maintenance & Reliability

Prevent flow-induced vibration in heat exchangers

ExxonMobil Research and Engineering Co.: Wanni, A. S.  |  Ruzek, Z. F.

New technology can be used in existing tube bundles to enable higher flowrates without risk of tube damage

What is new in API 610 11th Ed. (ISO 13709 2nd Ed.)?

Flowserve Corp.: Korkowski, F.
Consultant: Jones, R. L.

Updates to global specifications address pump reliability and much more

HP Reliability: Wire mesh vs. wire size for temporary strainers

Hydrocarbon Processing Staff: Bloch, Heinz P.

Even an experienced reliability professional may find some customary terminology dealing with wire gauge and wire mesh to be confusing. Our HPIn Reliability column of April 2009 mentioned pump suction..

Mitigate fouling in ebullated-bed hydrocrackers

Neste Engineering Solutions: Kunnas, J.
Baker Hughes: Ovaskainen, O.  |  Respini, M.

New monitoring tools help track and control asphaltene levels and solubility issues in resid products

Cost optimization in mechanical seal applications

Reliance Engineers Associates Ltd.: Chaware, D. K.  |  Shukla, D. K.  |  Swamy, R. B.

Real-life case studies prove it is possible to make more informed choices that often lead to cost savings

HP Reliability: Better equipment selection starts with understanding available upgrade options

Hydrocarbon Processing Staff: Bloch, Heinz P.

It all started with a letter we received from a major multinational petrochemical company: A reliability manager related that he had recently asked each maintenance department within the corporation&#..

Conduit body features double coating

The newly designed OCAL-BLUE Type 4X Form 8 conduit bodies from Thomas & Betts offer double-coated exteriors for enhanced protection in corrosive environments, as well as extending the service life of the conduit bodies.

Improve vacuum tower revamp projects

Sulzer Chemtech USA, Inc.: Costanzo, S.  |  Pilling, M.  |  Wong, S. M.

A ‘balanced approach’ investigates separation of vapor and liquids in the flash zone/wash section design

Mitigate corrosion in your crude unit

Nalco Company, Energy Services Division: Hilton, N. P.

Real-time analyzers can provide improved monitoring of chloride levels and enable better corrosion control practices

Case history 58: Piston pin plug wear

Consulting Engineer: Sofronas, A.

A wear analysis can help when failure data are meager